دوره 7، شماره 1 - ( 10-1394 )                   جلد 7 شماره 1 صفحات 42-37 | برگشت به فهرست نسخه ها

XML English Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Monadi M, Firouzjahi A, Hosseini A, Javadian Y, Sharbatdaran M, Heidari B. Serum C-reactive protein in asthma and its ability in predicting asthma control, a case-control study. Caspian J Intern Med 2016; 7 (1) :37-42
URL: http://caspjim.com/article-1-642-fa.html
Serum C-reactive protein in asthma and its ability in predicting asthma control, a case-control study. . 1394; 7 (1) :37-42

URL: http://caspjim.com/article-1-642-fa.html


چکیده:   (9935 مشاهده)

 Background: Increased serum high sensitive C-reactive protein (hs-CRP) in asthma and its association with disease severity has been investigated in many studies. This study aimed to determine serum hs-CRP status in asthma versus healthy controls and to examine its ability in predicting asthma control.

Methods: Serum CRP was measured by ELISA method using a high sensitive CRP kit. Severity of asthma was determined using Asthma Control Test. Spearman and chi square tests were used for association and correlation respectively. The predictive ability was determined by receiver operating characteristics (ROC) analysis. Accuracy was determined by determination of area under the ROC curve (AUC).

Results: A total of 120 patients and 115 controls were studied. Median serum hs-CRP in asthma was higher than control (P=0.001. In well controlled asthma the hs-CRP decreased significantly compared with poorly controlled (P=0.024) but still was higher than control (P=0.017). Serum hs-CRP at cutoff level of 1.45 mg/L differentiated the patients and controls with accuracy of 63.5 % (AUC= 0.635±0.037, P=0.001). Serum hs-CRP &le 2.15 mg/L predicted well controlled asthma with accuracy of 62.5% (AUC= 0.625±0.056, p=0.025). After adjusting for age, sex, weight and smoking, there was an independent association between serum hs-CRP >1.45 mg/L and asthma by adjusted OR=2.49, p=0.018).

Conclusion: These findings indicate that serum hs-CRP in asthma is higher than healthy control and increases with severity of asthma and decreases with. Thus, serum hs-CRP measurement can be helpful in predicting asthma control and treatment response.

متن کامل [PDF 140 kb]   (6329 دریافت)    
نوع مطالعه: Original Article | موضوع مقاله: Pulmonology
دریافت: 1394/7/28 | پذیرش: 1394/8/4 | انتشار: 1394/10/20

ارسال نظر درباره این مقاله : نام کاربری یا پست الکترونیک شما:
CAPTCHA

بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.

کلیه حقوق این وب سایت متعلق به می باشد.

طراحی و برنامه نویسی : یکتاوب افزار شرق

© 2024 CC BY-NC 4.0 | Caspian Journal of Internal Medicine

Designed & Developed by : Yektaweb