Tayebi P, Hasanzadeh K, Asgharpour M, Bijani A, Ziaie N. A cross-sectional study on non-infectious dysfunction of hemodialysis cuffed catheter. Caspian J Intern Med 2024; 15 (3) :439-443
URL: http://caspjim.com/article-1-4020-fa.html
A cross-sectional study on non-infectious dysfunction of hemodialysis cuffed catheter. . ۱۴۰۳; ۱۵ (۳) :۴۳۹-۴۴۳

URL: http://caspjim.com/article-۱-۴۰۲۰-fa.html


چکیده:   (۱۱۴۹ مشاهده)
Background: Dialysis cuffed catheter dysfunction results in inadequate dialysis, increased sepsis risk, and a shortened catheter life. It may be possible to prolong catheter function by identifying the causes of cuffed catheter dysfunction.
Methods: This study was a cross-sectional descriptive study conducted in 2021-2022 on hemodialysis patients with jugular cuff catheters. The catheterizations were performed using the Seldinger technique and were confirmed by fluoroscopy. A 12-month follow-up was conducted with respect to the performance of the cuffed catheter. 
Results: A total of 123 patients underwent hemodialysis over 2 years via a cuffed catheter. Catheters were most commonly inserted into the right internal jugular vein, with lengths of 19 cm (tip to cuff). The rate of dysfunction of cuffed catheters was 27.6%. Catheter-related thrombosis was the most common cause in 10 cases (29.4%), followed by catheter tip fibrin sheath in 8 cases (23.5%) and catheter tip malposition in 8 cases (23.5%). Furthermore, 18 patients (52.94%) of cuffed catheter dysfunction occurred within 3 months of catheter placement, based on our study. The dysfunction of cuffed catheters on the left side 23 (67.64%) is more prevalent than the right side 11 (32.35%) (P=0.043); the malposition of catheter tips is more prevalent on the left side (P=0.023).
Conclusion: Most commonly, cuffed catheter dysfunction is caused by thrombosis, fibrin sheath formation, and catheter tip malposition. Cuffed catheter failure can be reduced by carefully monitoring the catheter's path and tip position, searching for fibrin sheaths when investigating cuffed catheter failure, and preventing thrombotic events.

 
متن کامل [PDF 406 kb]   (۳۱۲ دریافت)    
نوع مطالعه: Original Article | موضوع مقاله: Nephrology
دریافت: 1402/4/30 | پذیرش: 1402/8/3 | انتشار: 1403/2/23

ارسال نظر درباره این مقاله : نام کاربری یا پست الکترونیک شما:
CAPTCHA

بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.

کلیه حقوق این وب سایت متعلق به می باشد.

طراحی و برنامه نویسی : یکتاوب افزار شرق

© 2025 CC BY-NC 4.0 | Caspian Journal of Internal Medicine

Designed & Developed by : Yektaweb