دوره 16، شماره 2 - ( 12-1403 )                   جلد 16 شماره 2 صفحات 238-233 | برگشت به فهرست نسخه ها


XML English Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Salehi Omran H, Balouchzadeh A, Dolatshahi S, Abrotan S, Salehi Omran M T, Saravi M, et al . The impact of cardiac resynchronization therapy with implantable cardioverter defibrillators on patients with moderate to severe chronic heart failure: A single-arm clinical trial. Caspian J Intern Med 2025; 16 (2) :233-238
URL: http://caspjim.com/article-1-4127-fa.html
The impact of cardiac resynchronization therapy with implantable cardioverter defibrillators on patients with moderate to severe chronic heart failure: A single-arm clinical trial. . 1403; 16 (2) :233-238

URL: http://caspjim.com/article-1-4127-fa.html


چکیده:   (297 مشاهده)
Background: Patients with moderate to severe chronic heart failure (CHF) are at high risk for cardiac mortality. Cardiac resynchronization therapy with defibrillators (CRT-D) as a potentially beneficial option can improve the clinical outcomes of such patients.
Methods: We conducted a single-arm clinical trial in which 48 patients with moderate to severe CHF were investigated regarding the beneficial outcome of CRT-D insertion. All participants were evaluated regarding different functional and echocardiographic factors including New York Heart Association (NYHA) functional class (FC), left ventricular ejection fraction (LVEF), mitral regurgitation (MR) as well as left ventricular end-systolic (LVESD) and end-diastolic (LVEDD) before and one month after the procedure. Furthermore, we investigated the influence of different variables including age, gender, and comorbidities on the aforementioned clinical and echocardiographic factors.
Results: Of the 48 CHF patients included in our study, 24 (50%) were males and 24 (50%) were females. The mean ± standard deviation (range) of the participants’ age was 55.6±6.5 (40-69) years. CRT-D insertion significantly improved all functional and echocardiographic factors in CHF patients. The participants had a mean±standard deviation (range) LVEF of 22.1±5.8% (10-30%) before CRT-D insertion. A follow-up echocardiography performed one month after the implantation of CRT-D demonstrated a significant increase in LVEF to 27.1±5.5% (15-38%) (p<0.001). Additionally, echocardiography conducted one month after CRT-D insertion showed a reduction of LVESD from 6.8±0.5 cm (5.8-7.4 cm) to 6.2±0.5 cm (5.3-7.3 cm) (p<0.001).
Conclusion: There is prominent evidence for CRT-D insertion in reducing symptoms of heart failure as well as improving different echocardiography variables in patients with moderate to severe CHF.

 
متن کامل [PDF 537 kb]   (31 دریافت)    
نوع مطالعه: Original Article | موضوع مقاله: Cardiology
دریافت: 1402/7/27 | پذیرش: 1402/11/2 | انتشار: 1403/12/21

ارسال نظر درباره این مقاله : نام کاربری یا پست الکترونیک شما:
CAPTCHA

بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.

کلیه حقوق این وب سایت متعلق به می باشد.

طراحی و برنامه نویسی : یکتاوب افزار شرق

© 2025 CC BY-NC 4.0 | Caspian Journal of Internal Medicine

Designed & Developed by : Yektaweb