دوره 16، شماره 1 - ( 11-1403 )                   جلد 16 شماره 1 صفحات 184-178 | برگشت به فهرست نسخه ها


XML English Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Akbarzadehpasha A, Lotfi Z, Omidvar R, Goodarzi A, Hosseini S, Sadeghzadeh Bazargan A et al . Recurrent prosthetic mitral valve thrombosis: The first report of an unusual feature of systemic mastocytosis, a case report and review of the literature.. Caspian J Intern Med 2025; 16 (1) :178-184
URL: http://caspjim.com/article-1-3642-fa.html
Recurrent prosthetic mitral valve thrombosis: The first report of an unusual feature of systemic mastocytosis, a case report and review of the literature.. . 1403; 16 (1) :178-184

URL: http://caspjim.com/article-1-3642-fa.html


چکیده:   (954 مشاهده)

Background: Mastocytosis is a systemic disease involving the clonal expansion of mast cells in multiple organs. Given that immune system overreaction and excessive histamine release are among the most prominent events in mastocytosis, the incidence of complications caused by immune reactions is expected to increase across various organs. While systemic manifestations of mastocytosis have been reported frequently, cardiac complications are less often discussed. These Cardiac complications can be early indicators of the disease but such uncommon features may lead to delays in diagnosis.
The significance of mast cells and histamine release in the cardiovascular system is acknowledged in prior studies.
Case Presentation: This study presents a case of recurrent prosthetic mitral valve malfunction in a 52-year-old patient with a history of cutaneous mastocytosis, who underwent mitral valve replacement three times over ten years. Despite being on appropriate anticoagulation therapy (INR: 2.5-3.5), the patient experienced recurrent prosthetic valve thrombosis. This is, to our knowledge, the first report of prosthetic mitral valve thrombosis in a patient with mastocytosis.
Conclusion: Interestingly, cardiac complications may be the first presentation of systemic mastocytosis, diagnosed long after the initial symptoms. The majority of such cases had no visible cutaneous manifestations (table 1). Regarding our case report, we recommend our colleagues to closely monitor and remain vigilant for possible cardiac symptoms of mastocytosis patients with prosthetic cardiac valves.

 

متن کامل [PDF 557 kb]   (267 دریافت)    
نوع مطالعه: case report | موضوع مقاله: Cardiology
دریافت: 1401/6/12 | پذیرش: 1401/10/3 | انتشار: 1404/7/28

ارسال نظر درباره این مقاله : نام کاربری یا پست الکترونیک شما:
CAPTCHA

بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.

کلیه حقوق این وب سایت متعلق به می باشد.

طراحی و برنامه نویسی : یکتاوب افزار شرق

© 2025 CC BY-NC 4.0 | Caspian Journal of Internal Medicine

Designed & Developed by : Yektaweb