دوره 17، شماره 1 - ( 10-1404 )                   جلد 17 شماره 1 صفحات 142-136 | برگشت به فهرست نسخه ها

XML English Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Moudi E, Mollaei M, Haghanifar S, Gholampour A, Bijani A. Accuracy of bone height and thickness measurements in cone beam computed tomography using different voxel sizes in maxilla and mandible. Caspian J Intern Med 2026; 17 (1) :136-142
URL: http://caspjim.com/article-1-4649-fa.html
Accuracy of bone height and thickness measurements in cone beam computed tomography using different voxel sizes in maxilla and mandible. . 1404; 17 (1) :136-142

URL: http://caspjim.com/article-1-4649-fa.html


چکیده:   (51 مشاهده)

Background: Cone Beam Computed Tomography (CBCT) is used to evaluate the hard tissue of the maxillofacial area, and the dose received by the patient depends on the resolution of the images. This study investigated the effect of CBCT resolution (voxel size) on its linear measurement accuracy.
Methods: This in vitro study was conducted on 19 human mandibles and 11 dry maxillae. On each jaw, four anterior and four posterior regions were examined. Markers were placed in the designated areas using gutta-percha. The jaws were scanned at three voxel sizes (100, 150, 200 µm). The bone height and thickness were measured in the prepared images and compared with the sizes obtained. Paired t-test, t-test, one-way ANOVA, and Tukey’s post-hoc tests were used for statistical analysis.
Results: Buccal and lingual bone height measurements showed significant differences across voxel sizes (p < 0.05), with higher resolution (100 µm) yielding greater accuracy. No significant difference was found in bone thickness measurements between resolutions (p = 0.20). Height measurements were significantly less accurate in anterior than posterior regions (p < 0.05). No significant difference was observed between maxilla and mandible except for buccal height at medium and standard resolutions. All CBCT measurements underestimated actual dimensions. Thickness measurements were more accurate than height measurements.
Conclusion: Using high resolution in CBCT machines is recommended to reduce linear measurement error when there is a short distance to the critical anatomical structures.

 

متن کامل [PDF 441 kb]   (15 دریافت)    
نوع مطالعه: Original Article | موضوع مقاله: Radiology
دریافت: 1403/10/15 | پذیرش: 1404/2/15 | انتشار: 1404/11/1

ارسال نظر درباره این مقاله : نام کاربری یا پست الکترونیک شما:
CAPTCHA

بازنشر اطلاعات
Creative Commons License این مقاله تحت شرایط Creative Commons Attribution-NonCommercial 4.0 International License قابل بازنشر است.

کلیه حقوق این وب سایت متعلق به می باشد.

طراحی و برنامه نویسی : یکتاوب افزار شرق

© 2026 CC BY-NC 4.0 | Caspian Journal of Internal Medicine

Designed & Developed by : Yektaweb