[Home ] [Archive]    
:: Main :: About :: Current Issue :: Archive :: Search :: Submit :: Contact ::
Main Menu
Home::
Journal Information::
Articles archive::
For Authors::
For Reviewers::
Registration::
Contact us::
Site Facilities::
::
Impact Factor 2022: 1.4
Cite Score 2022: 2.1
SJR 2022: 0.347
SNIP 2022: 0.545
..
Publication Charge
►Publication Fee
..
In Press
 In Press Articles
..
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
:: Volume 3, Issue 3 (1-2012) ::
Caspian J Intern Med 2012, 3(3): 478-483 Back to browse issues page
Quantification and comparison of bone-specific alkaline phosphatase with two methods in normal and paget’s specimens
Jila Masrour Roudsari , Soleiman Mahjoub
Abstract:   (7806 Views)
Background: Bone-specific alkaline phosphatase (BAP) is synthesized by the osteoblasts and is presumed to be involved in the calcification of bone matrix, though its precise role in the formation process is unknown. The aim of the present study was to measure the BAP activity in Paget's and normal specimens by two different techniques.
Methods: Total ALP (TAP) as well as BAP activity-measuring tests were repeatedly undertaken at different times during the day and different days on the serum samples (inter and intra assay). Precision and repeatability of the phenylalanine inhibition (PHI) and heat inactivation (HI) techniques were approved during ten times repetition of all the tests on two normal samples besides one sample from Paget's disease of bone. The measurement of TAP and BAP activities was also carried out on 50 serum samples from normal adults using the standard IFCC-AACC and the established methods, respectively.
Results: Coefficients of Variation (CV) for intra-assay of BAP were 2.33% and 3.16% by HI and PHI methods, respectively. Also, the inter-assay CV of BAP was 2.87% and 3.49% for mentioned methods in Paget's sample, respectively. In addition, the correlation of HI and PHI methods was found to be r= +0.873 for bone-specific isoenzyme.
Conclusion: Regarding the appropriate precision, repeatability and correlation of HI and PHI techniques, as well as their cost effectiveness can be of use in the quantification of bone alkaline phosphatase isoenzyme activity, especially when bone is involved.
Keywords: Bone-specific isoenzyme, Bone marker, Phenylalanine inhibition, Heat inactivation, Paget\'s disease
Full-Text [PDF 125 kb]   (3352 Downloads)    
Type of Study: Original Article | Subject: Infectious Diseases
Received: 2014/01/15 | Accepted: 2014/01/15 | Published: 2014/01/15
Add your comments about this article
Your username or Email:

CAPTCHA


XML     Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Masrour Roudsari J, Mahjoub S. Quantification and comparison of bone-specific alkaline phosphatase with two methods in normal and paget’s specimens. Caspian J Intern Med 2012; 3 (3) :478-483
URL: http://caspjim.com/article-1-160-en.html


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
Volume 3, Issue 3 (1-2012) Back to browse issues page
Caspian Journal of Internal Medicine
Persian site map - English site map - Created in 0.05 seconds with 40 queries by YEKTAWEB 4645